FluidCool-X™

Intelligent Cooling for Demanding AI Infrastructure

FluidCool-X CDU is purpose-built to solve the thermal challenges of next-gen AI hardware and high-density compute environments. Its cutting-edge technology allows operators to scale cooling quickly, maintain uptime, and stay ahead of rising thermal loads.

When performance is non-negotiable, FluidCool-X delivers.

Our immersive virtual and augmented reality platform brings our innovative cooling solutions directly to you.

See how AIRSYS technology seamlessly integrates into your specific telecom or data center environment.

  • Integrated energy efficiency features achieve an ultra-low PUE <1.05.
  • VFD pumps adjust flow to cut energy use by up to 30%.
  • High-efficiency plate heat exchangers improve cooling with a smaller footprint.
  • 4K ultra-tight approach temp maximizes heat exchange for higher return water temps and better energy recovery.
  • BPHE water reuse design supports efficient closed-loop cooling and minimizes waste.
  • Precision two-way valves regulate flow in real time, reducing overcooling and unnecessary energy use.
  • Available in 500kW/1000kW/2000kW configurations.
  • Modular units scale in hours and are managed through a single unified interface.
  • Hot-swappable components, quick-connect piping, and front access simplify service and maintenance.
  • Smart sensors monitor pH, conductivity, temperature, and pressure with built-in redundancy for uptime.
  • Leak detection, corrosion protection, and fail-safe controls protect infrastructure from system failures.
  • High-flow pump (250 GPM) with strong head pressure supports multi-rack loads.
  • Triple-layer redundancy delivers 99.999% uptime.
  • Low ΔT operation enhances thermal reliability and cooling precision.
  • High energy efficiency and optimized water usage contribute to sustainability goals.
  • Extended lifespan and easy maintenance reduce service time and replacement costs.
  • Rapid deployment and built-in scalability shorten time-to-operation.
  • Consistent uptime, reliability, and energy-efficient operation drive sustained ROI.

Always On, Always Protected

FluidCool-X safeguards uptime with triple-layer redundancy at the component, power, and control levels, so cooling stays uninterrupted, even when other systems don’t.

Redefining CDU Efficiency

Approach Temperature is a defining indicator of cooling efficiency and system stability, and FluidCool-X sets a new standard. Its exceptionally low 4°C (7.2°F) approach temperature not only provides a clear competitive edge, but also brings added benefits that improve thermal performance across the system.

Industry Benchmarks:

  • Traditional CDU:
    8–10°C (14.4–18°F)
  • Optimized CDU:
    6°C (10.8°F)
  • FluidCool-X:
    4°C (7.2°F)

The Results:

  • Higher Chiller Efficiency
  • More Stable Outlet Temperatures
  • Faster Thermal Response
  • Better Water-Side ΔT Utilization
How energy-efficient is FluidCool-X?
FluidCool-X leverages liquid cooling's natural heat transfer efficiency and enhances it with integrated energy-efficient features like VFD pumps, high-efficiency heat exchangers, smart load balancing, and ultra-tight approach temperatures. Together, these technologies enable FluidCool-X to achieve a remarkable PUE of less than 1.05. Reduced energy costs are also a testament to the system’s energy-efficiency capabilities. Read more about data center energy efficiency metrics.
What makes FluidCool-X different from traditional liquid cooling systems?
FluidCool-X stands apart through a combination of advanced technology, deep market understanding, and a forward-looking design philosophy. Every aspect of the unit is designed with intention, from energy efficiency and simplified maintenance to hardware longevity and seamless scalability. Unlike traditional systems that are focused solely on current specs, FluidCool-X anticipates the operational realities of high-density environments and evolving workloads. This mindset offers operators powerful performance in a system that’s intuitive to deploy, manage, and trust long-term.
How does FluidCool-X support sustainability efforts for data centers?
FluidCool-X supports sustainability in multiple ways. First, its closed-loop liquid cooling system enables water reuse and minimizes waste. Also, energy-efficient components, such as VFD pumps, high-efficiency heat exchangers, and precision control logic, optimize performance while reducing unnecessary energy draw, often by about 30%. These features help data centers meet ESG targets and support long-term sustainability strategies. Read more about the role of cooling in green data centers.
Can FluidCool-X be deployed in existing data centers or only in new builds?
FluidCool-X is designed for flexibility, making it ideal for both retrofits and new deployments. Its rack-level footprint, quick-connect piping, and scalable modular design allow seamless integration into existing infrastructure with minimal disruption.
Can I customize FluidCool-X to fit my data center's needs?
Yes. All AIRSYS cooling solutions can be tailored to your facility to optimize performance, reduce power consumption, and increase operational efficiency. Talk to our specialists today to discuss the best options for your deployments.

Cooling You Can Count On with a Team You Can Trust

When you choose AIRSYS, you invest in your success.

FluidCool-X is built on 30+ years of engineering expertise and backed by a global team committed to innovation, long-term reliability, and sustainable performance. With AIRSYS, you gain more than a solution; you gain a committed partner every step of the way.