Airsys Unveils Arc90, a Thermal Management Architecture Designed to Allocate Up to 90% of Data Center Power to Compute
November 16, 2026Thermal management technology restored full capacity 160 seconds after backup generators engaged and delivered 500+ tons of cooling per unit with zero water consumption
WOODRUFF, S.C. — Nov. 24, 2026 — Airsys, a provider of mission-critical cooling and infrastructure solutions, today announced that its VectorCool™ chiller passed all nine key evaluation categories during AI-load stress testing at a globally recognized third-party test facility. The testing was conducted with a fast-growing European GPU-as-a-Service (GPUaaS) provider that selected VectorCool to cool its high-density AI infrastructure.
AI-focused data centers can draw anywhere from 50 to more than 100 megawatts (MW) of power, and nearly all of it becomes heat. Cooling requirements at these facilities often reach 15,000 to 30,000 tons, and traditional chiller technologies can struggle to keep up as GPU clusters grow more thermally dense. The provider needed a chiller that could support extreme GPU heat loads, scale quickly with AI demand, integrate with both liquid-cooled and air-cooled systems and restart rapidly after a power interruption, all within a footprint of 43.5 feet or less.
Before installation, Airsys and the provider partnered to validate VectorCool’s performance at 100 percent, 75 percent and 50 percent load points, along with a fast-restart scenario simulating an unexpected power outage. Once backup generators engaged, the VectorCool unit returned to full load capacity in just 160 seconds. The multi-load testing confirmed the chiller’s ability to perform across varying heat loads and seasonal conditions.
Read the full VectorCool™ customer story for the complete test results.
“Operators building AI capacity today are working against aggressive timelines, and they need cooling equipment that shows up ready to perform,” said Sean Corcoran, vice president of sales – PowerOne at Airsys. “This provider asked us to prove VectorCool under AI-scale heat loads before a single unit was installed. Passing every evaluation category, and designing a unit that ships on standard highway routes, shows we can deliver both the cooling capacity and the speed that AI deployments demand.”
Key performance figures included:
- High capacity: More than 500 tons of cooling capacity per chiller unit.
- Energy savings: Chiller energy savings of 20 percent to 70 percent driven by magnetic bearing compressors that eliminate mechanical friction in the bearing system and pumps that use 50 percent less energy.
- Low ambient operation: Operates at outdoor temperatures as low as -13°F, where cooler air improves heat rejection and reduces compressor workload.
- Zero water consumption: A closed-loop design meets the site’s requirement for waterless operation in a region with summer highs above 100°F and freezing winters.
Airsys also customized the unit’s dimensions so it could be transported on highways without special escorts or permits, reducing logistics costs for the project.
“AI facilities are pushing heat loads well past what traditional chiller plants were built to handle, and operators can’t afford long recovery times when power is interrupted,” said Everett Hettema, senior project manager – PowerOne at Airsys. “Seeing VectorCool return to full load capacity within 160 seconds of generator startup and hold stable cooling across every load point tested gives operators confidence that their cooling can keep pace with their compute buildout.”
Because VectorCool’s variable-speed components reduce the chiller plant’s peak power demand, operators can provision a larger share of total facility power to compute. That raises the facility’s Power Compute Effectiveness (PCE), a metric introduced by Airsys and published by the Open Compute Project (OCP), defined as provisioned power for compute divided by provisioned total data center power.
VectorCool supplies chilled water to both liquid-cooled and air-cooled portions of a facility and offers multiple compressor configurations. Embedded redundancy keeps one circuit operational while the other is serviced, and an open architecture simplifies integration with other facility systems. The platform scales from 500 kW to 2 MW, while AI-driven controls and remote sensors adjust chiller operation in real time to reduce energy use. Standardized sub-modules shorten maintenance time and reduce material waste.
Airsys’ 245,000-plus-square-foot production facility in Woodruff, South Carolina, along with strategically located global facilities, supports fast component distribution, backed by a growing network of server and infrastructure OEM partners.
ABOUT AIRSYS
Airsys provides mission-critical cooling for high-performing digital infrastructure, including data centers, AI, edge computing, telecom, medical imaging and advanced manufacturing environments. Airsys combines more than 30 years of technical excellence designing and delivering cooling solutions across all major thermal architectures – air, liquid and hybrid – with a purpose-driven focus on energy efficiency and sustainability.
With its unique focus on ensuring higher Power Compute Effectiveness (PCE), Airsys helps customers allocate a larger share of their provisioned power to compute. The company is headquartered in South Carolina, USA, and supports its global mission with 1,000+ employees across 16 global locations. For more information, visit airsyscooling.com.